Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Clinical Pain ; (2): 33-37, 2023.
Article in English | WPRIM | ID: wpr-1000697

ABSTRACT

The facet joints are a common source of chronic spinal pain. Blocks of the nerves supplying the facet joints are validated tools in the diagnosis and treatment for facet joint pain. These interventions are typically performed with fluoroscopic guidance. However, the target, which is the nerve, is radiolucent and cannot be identified with fluoroscopy. Recently, several ultrasound guided techniques in the domain of spinal pain have been emerging because ultrasound is useful in visualization of the inner structures, is portable, and is not associated with the radiation exposure. This paper reviews a variety of techniques for ultrasound guided interventions for the medial branch block which has been reported in treating axial pain originating from the facet joint.

2.
Annals of Rehabilitation Medicine ; : 261-271, 2023.
Article in English | WPRIM | ID: wpr-999388

ABSTRACT

Objective@#To assess the accuracy of recently commercialized wearable devices in heart rate (HR) measurement during cardiopulmonary exercise test (CPX) under gradual increase in exercise intensity, while wearable devices with HR monitors are reported to be less accurate in different exercise intensities. @*Methods@#CPX was performed for patients with coronary artery disease (CAD). Twelve lead electrocardiograph (ECG) was the gold standard and Apple watch 7 (AW7), Galaxy watch 4 (GW4) and Bio Patch Mobicare 200 (MC200) were applied for comparison. Paired absolute difference (PAD), mean absolute percentage error (MAPE) and intraclass correlation coefficient (ICC) were evaluated for each device. @*Results@#Forty-four participants with CAD were included. All the devices showed MAPE under 2% and ICC above 0.9 in rest, exercise and recovery phases (MC200=0.999, GW4=0.997, AW7=0.998). When comparing exercise and recovery phase, PAD of MC200 and AW7 in recovery phase were significantly bigger than PAD of exercise phase (p<0.05). Although not significant, PAD of GW4 tended to be bigger in recovery phase, too. Also, when stratified by HR 20, ICC of all the devices were highest under HR of 100, and ICC decreased as HR increased. However, except for ICC of GW4 at HR above 160 (=0.867), all ICCs exceeded 0.9 indicating excellent accuracy. @*Conclusion@#The HR measurement of the devices validated in this study shows a high concordance with the ECG device, so CAD patients may benefit from the devices during high-intensity exercise under conditions where HR is measured reliably.

3.
Annals of Rehabilitation Medicine ; : 150-159, 2021.
Article in English | WPRIM | ID: wpr-896918

ABSTRACT

Objective@#To examine whether patients who participated in a cardiac rehabilitation (CR) program after hospitalization for acute coronary syndrome maintained cardiorespiratory fitness (CRF) in the community. @*Methods@#We conducted a retrospective study including 78 patients who underwent percutaneous coronary intervention or coronary artery bypass graft surgery at our hospital’s cardiovascular center and participated in a CR program and a 5-year follow-up evaluation. Patients were divided into a center-based CR (CBCR) group, participating in an electrocardiography-monitored exercise training in a hospital setting, and a home-based CR (HBCR) group, receiving aerobic exercise training and performed self-exercise at home. @*Results@#No significant differences were found between groups (p>0.05), except the proportion of non-smokers (CBCR 59.5% vs. HBCR 31.7%; p=0.01). In both groups, the maximal oxygen consumption (VO2max) increased significantly during the first 12 weeks of follow-up and remained at a steady state for the first year, but it decreased after the 1-year follow-up. Particularly, VO2max at 5 years decreased below the baseline value in the HBCR group. In the low CRF group, the CRF level significantly improved at 12 weeks, peaked at 1 year, and was still significantly different from the baseline value after 5 years. The high CRF group did not show any significant increase over time relative to the baseline value, but most patients in the high CRF group maintained relatively appropriate CRF levels after 5 years. @*Conclusion@#Continuous support should be provided to patients to maintain optimal CRF levels after completing a CR program.

4.
Annals of Rehabilitation Medicine ; : 150-159, 2021.
Article in English | WPRIM | ID: wpr-889214

ABSTRACT

Objective@#To examine whether patients who participated in a cardiac rehabilitation (CR) program after hospitalization for acute coronary syndrome maintained cardiorespiratory fitness (CRF) in the community. @*Methods@#We conducted a retrospective study including 78 patients who underwent percutaneous coronary intervention or coronary artery bypass graft surgery at our hospital’s cardiovascular center and participated in a CR program and a 5-year follow-up evaluation. Patients were divided into a center-based CR (CBCR) group, participating in an electrocardiography-monitored exercise training in a hospital setting, and a home-based CR (HBCR) group, receiving aerobic exercise training and performed self-exercise at home. @*Results@#No significant differences were found between groups (p>0.05), except the proportion of non-smokers (CBCR 59.5% vs. HBCR 31.7%; p=0.01). In both groups, the maximal oxygen consumption (VO2max) increased significantly during the first 12 weeks of follow-up and remained at a steady state for the first year, but it decreased after the 1-year follow-up. Particularly, VO2max at 5 years decreased below the baseline value in the HBCR group. In the low CRF group, the CRF level significantly improved at 12 weeks, peaked at 1 year, and was still significantly different from the baseline value after 5 years. The high CRF group did not show any significant increase over time relative to the baseline value, but most patients in the high CRF group maintained relatively appropriate CRF levels after 5 years. @*Conclusion@#Continuous support should be provided to patients to maintain optimal CRF levels after completing a CR program.

SELECTION OF CITATIONS
SEARCH DETAIL